332 research outputs found

    A novel non-invasive device for the assessment of central venous pressure in hospital, office and home

    Get PDF
    Background: Venous congestion can be quantified by central venous pressure (CVP) and its monitoring is crucial to understand and follow the hemodynamic status of patients with cardio-respiratory diseases. The standard technique for CVP measurement is invasive, requiring the insertion of a catheter into a jugular vein, with potential complications. On the other hand, the current non-invasive methods, mainly based on ultrasounds, remain operator-dependent and are unsuitable for use in the home environment. In this paper, we will introduce a novel, non-invasive device for the hospital, office and home assessment of CVP. Methods: After describing the measurement concept, we will report a preliminary experimental study enrolling 5 voluntary healthy subjects to evaluate the VenCoM measurements’ repeatability, and the system’s capability in measuring small elicited venous pressure variations (2 mmHg), as well as an induced venous hypertension within a pathological range (12÷20 mmHg). Results: The experimental measurements showed a repeatability of ±1mmHg. The VenCoM device was able to reliably detect the elicited venous pressure variations and the simulated congestive status. Discussion and Conclusion: The proposed non-invasive VenCoM device is able to provide a fast and repeatable CVP estimate, having a wide spectrum of potential clinical applications, including the monitoring of venous congestion in heart failure patients and in subjects with renal and hepatic dysfunction, as well as pulmonary hypertension (PH) that can be extended to pneumonia COVID-19 patients even after recovery. The device needs to be tested further on a large sample size of both healthy and pathological subjects, to systematically validate its reliability and impact in clinical setting

    Utility of blotting paper for serological tests to perform monitoring programs for European Brown Hare Syndrome (EBHS)

    Get PDF
    Since mid \u201880 the European brown hare (Lepus europeaus) populations have been progressively declining due to several causes, including the occurrence of EBHS. After the first outbreaks in North Italy in the \u201990, the periodical EBHS cases imposed the adoption of an articulate monitoring plan of the different hare populations, including those from protected areas and the hunting territory. In addition to the examination of dead animals for viral detection, such monitoring activity takes advantage from serological survey i.e. by checking the presence of antibodies to EBHSV. Since different types of blood sampling may be adopted according to each situation, from 2005 to 2012, we planned to compare the serological titres obtained by testing with cELISA: a) the \u201cclassical\u201d serum b) samples of blood dried onto blotting paper and c) bloody fluid from the heart cavities. The major aim was to establish the utility of each sampling method for verifying hares\u2019 health status and the possibility to get data from low density areas, as hunting ones. We analysed the following samples: a) + b = 305 animals; b) + c) = 182 animals; a) + c) = 95 animals. Even if blotting paper and cardiac blood slightly underestimate the EBHSV antibody titres, both these \u201calternative\u201d sampling methods may be useful for field studies. Moreover, the slightly underestimates of antibody titres do not prevent to correctly interpret the sero-epidemiological results with regard to the understanding of spatial/time exposure of the population to EBHS and the ability of single hares to resist the EBHSV infection

    In Car Audio

    Get PDF
    This chapter presents implementations of advanced in Car Audio Applications. The system is composed by three main different applications regarding the In Car listening and communication experience. Starting from a high level description of the algorithms, several implementations on different levels of hardware abstraction are presented, along with empirical results on both the design process undergone and the performance results achieved

    Comparative susceptibility of eastern cottontails and New Zealand white rabbits to classical rabbit haemorrhagic disease virus (RHDV) and RHDV2

    Get PDF
    Rabbit haemorrhagic disease virus (RHDV) is associated with high morbidity and mortality in the European rabbit (Oryctolagus cuniculus). In 2010, a genetically distinct RHDV named RHDV2 emerged in Europe and spread to many other regions, including North America in 2016. Prior to this study it was unknown if eastern cottontails (ECT(s); Sylvilagus floridanus), one of the most common wild lagomorphs in the United States, were susceptible to RHDV2. In this study, 10 wild-caught ECTs and 10 New Zealand white rabbits (NZWR(s); O. cuniculus) were each inoculated orally with either RHDV (RHDVa/GI.1a; n = 5 per species) or RHDV2 (a recombinant GI.1bP-GI.2; n = 5 per species) and monitored for the development of disease. Three of the five ECTs that were infected with RHDV2 developed disease consistent with RHD and died at 4 and 6 days post-inoculation (DPI). The RHDV major capsid protein/antigen (VP60) was detected in the livers of three ECTs infected with RHDV2, but none was detected in the ECTs infected with RHDV. Additionally, RHD viral RNA was detected in the liver, spleen, intestine and blood of ECTs infected with RHDV2, but not in the ECTs infected with RHDV. RHD viral RNA was detected in urine, oral swabs and rectal swabs in at least two of five ECTs infected with RHDV2. One ECT inoculated with RHDV2 seroconverted and developed a high antibody titre by the end of the experimental period (21 DPI). ECTs inoculated with the classic RHDV did not seroconvert. In comparison, NZWRs inoculated with RHDV2 exhibited high mortality (five of five) at 2 DPI and four of five NZWRs inoculated with RHDV either died or were euthanized at 2 DPI indicating both of these viruses were highly pathogenic to this species. This experiment indicates that ECTs are susceptible to RHDV2 and can shed viral RNA, thereby suggesting this species could be involved in the epidemiology of this virus

    A pandemic strain of calicivirus threatens rabbit industries in the Americas

    Get PDF
    Rabbit Hemorrhagic Disease (RHD) is a severe acute viral disease specifically affecting the European rabbit Oryctolagus cuniculus. As the European rabbit is the predominant species of domestic rabbit throughout the world, RHD contributes towards significant losses to rabbit farming industries and endangers wild populations of rabbits in Europe and other predatory animals in Europe that depend upon rabbits as a food source. Rabbit Hemorrhagic Disease virus (RHDV) – a Lagovirus belonging to the family Caliciviridae is the etiological agent of RHD. Typically, RHD presents with sudden death in 70% to 95% of infected animals. There have been four separate incursions of RHDV in the USA, the most recent of which occurred in the state of Indiana in June of 2005. Animal inoculation studies confirmed the pathogenicity of the Indiana 2005 isolate, which caused acute death and pathological changes characterized by acute diffuse severe liver necrosis and pulmonary hemorrhages. Complete viral genome sequences of all USA outbreak isolates were determined and comparative genomics revealed that each outbreak was the result of a separate introduction of virus rather than from a single virus lineage. All of the USA isolates clustered with RHDV genomes from China, and phylogenetic analysis of the major capsid protein (VP60) revealed that they were related to a pandemic antigenic variant strain known as RHDVa. Rapid spread of the RHDVa pandemic suggests a selective advantage for this new subtype. Given its rapid spread, pathogenic nature, and potential to further evolve, possibly broadening its host range to include other genera native to the Americas, RHDVa should be regarded as a threat

    West Nile virus: characterization and diagnostic applications of monoclonal antibodies

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Diagnosis of West Nile virus (WNV) infections is often difficult due to the extensive antigenic cross-reactivity among flaviviruses, especially in geographic regions where two or more of these viruses are present causing sequential infections. The purpose of this study was to characterize a panel of monoclonal antibodies (MAbs) produced against WNV to verify their applicability in WNV diagnosis and in mapping epitope targets of neutralizing MAbs.</p> <p>Methods</p> <p>Six MAbs were produced and characterized by isotyping, virus-neutralization, western blotting and MAb-epitope competition. The MAb reactivity against various WNVs belonging to lineage 1 and 2 and other related flaviviruses was also evaluated. The molecular basis of epitopes recognized by neutralizing MAbs was defined through the selection and sequencing of MAb escape mutants. Competitive binding assays between MAbs and experimental equine and chicken sera were designed to identify specific MAb reaction to epitopes with high immunogenicity.</p> <p>Results</p> <p>All MAbs showed stronger reactivity with all WNVs tested and good competition for antigen binding in ELISA tests with WNV-positive equine and chicken sera. Four MAbs (3B2, 3D6, 4D3, 1C3) resulted specific for WNV, while two MAbs (2A8, 4G9) showed cross-reaction with Usutu virus. Three MAbs (3B2, 3D6, 4D3) showed neutralizing activity. Sequence analysis of 3B2 and 3D6 escape mutants showed an amino acid change at E307 (Lys → Glu) in the E protein gene, whereas 4D3 variants identified mutations encoding amino acid changed at E276 (Ser → Ile) or E278 (Thr → Ile). 3B2 and 3D6 mapped to a region on the lateral surface of domain III of E protein, which is known to be a specific and strong neutralizing epitope for WNV, while MAb 4D3 recognized a novel specific neutralizing epitope on domain II of E protein that has not previously been described with WNV MAbs.</p> <p>Conclusions</p> <p>MAbs generated in this study can be applied to various analytical methods for virological and serological WNV diagnosis. A novel WNV-specific and neutralizing MAb (4D3) directed against the unknown epitope on domain II of E protein can be useful to better understand the role of E protein epitopes involved in the mechanism of WNV neutralization.</p

    Twenty-five years in the making: flecainide is safe and effective for the management of atrial fibrillation

    Get PDF
    Atrial fibrillation (AF) is the most common arrhythmia in clinical practise and its prevalence is increasing. Over the last 25 years, flecainide has been used extensively worldwide, and its capacity to reduce AF symptoms and provide long-term restoration of sinus rhythm (SR) has been well documented. The increased mortality seen in patients treated with flecainide in the Cardiac Arrhythmia Suppression Trial (CAST) study, published in 1991, still deters many clinicians from using flecainide, denying many new AF patients a valuable treatment option. There is now a body of evidence that clearly demonstrates that flecainide has a favourable safety profile in AF patients without significant left ventricular disease or coronary heart disease. As a result of this evidence, flecainide is now recommended as one of the first-line treatment options for restoring and maintaining SR in patients with AF under current treatment guidelines. The objective of this article is to review the literature pertaining to the pharmacological characteristics, safety and efficacy of flecainide, and to place this drug in the context of current therapeutic management strategies for AF

    How to use implantable loop recorders in clinical trials and hybrid therapy

    Get PDF
    Epidemiological studies show that atrial fibrillation (AF) is associated with a doubling of mortality, even after adjustment for confounders. AF can be asymptomatic, but this does not decrease the thromboembolic risk of the patient. Office ECGs, occasional 24-h Holter recordings and long-term ECG event recording might not be sensitive and accurate enough in patients with AF, especially in those with paroxysmal episodes. In one study, 7 days of continuous monitoring with event recorders detected paroxysmal AF in 20 of 65 patients with a previous negative 24-h Holter recording. Over the last decade, enormous improvements have been made in the technology of implantable devices, which can now store significant information regarding heart rhythm. The first subcutaneous implantable monitor (Reveal XT, Medtronic) was validated for continuous AF monitoring by the XPECT study. The dedicated AF detection algorithm uses irregularity and incoherence of R–R intervals to identify and classify patterns in ventricular conduction. Its sensitivity in identifying patients with AF is >96%. Numerous clinical data from continuous monitoring of AF have recently been published. The first applications of this technology have been in the field of surgical and catheter AF ablation. With regard to cryptogenic stroke, an international randomized trial is ongoing to compare standard care with standard care plus the implantable cardiac monitor for AF detection in patients discharged with the diagnosis of cryptogenic stroke: the Crystal AF trial. Continuous AF monitoring provides an optimal picture of daily AF burden, both symptomatic and asymptomatic. Implantable cardiac monitors have high sensitivity, enable better assessment of therapy success and may guide further AF therapy

    Long-Term Implications of Atrial Fibrillation in Patients With Degenerative Mitral Regurgitation

    Get PDF
    Background: Scientific guidelines consider atrial fibrillation (AF) complicating degenerative mitral regurgitation (DMR) a debated indication for surgery. Objectives: This study analyzed the prognostic/therapeutic implications of AF at DMR diagnosis and long-term. Methods: Patients were enrolled in the MIDA (Mitral Regurgitation International Database) registry, which reported the consecutive, multicenter, international experience with DMR due to flail leaflets echocardiographically diagnosed. Results: Among 2,425 patients (age 67 \ub1 13 years; 71% male, 67% asymptomatic, ejection fraction 64 \ub1 10%), 1,646 presented at diagnosis with sinus rhythm (SR), 317 with paroxysmal AD, and 462 with persistent AF. Underlying clinical/instrumental characteristics progressively worsened from SR to paroxysmal to persistent AF. During follow-up, paroxysmal and persistent AF were associated with excess mortality (10-year survival in SR and in paroxysmal and persistent AF was 74 \ub1 1%, 59 \ub1 3%, and 46 \ub1 2%, respectively; p &lt; 0.0001), that persisted 20 years post-diagnosis and independently of all baseline characteristics (p values &lt;0.0001). Surgery (n = 1,889, repair 88%) was associated with better survival versus medical management, regardless of all baseline characteristics and rhythm (adjusted hazard ratio: 0.26; 95% confidence interval: 0.23 to 0.30; p &lt; 0.0001) but post-surgical outcome remained affected by AF (10-year post-surgical survival in SR and in paroxysmal and persistent AF was 82 \ub1 1%, 70 \ub1 4%, and 57 \ub1 3%, respectively; p &lt; 0.0001). Conclusions: AF is a frequent occurrence at DMR diagnosis. Although AF is associated with older age and more severe presentation of DMR, it is independently associated with excess mortality long-term after diagnosis. Surgery is followed by improved survival in each cardiac rhythm subset, but persistence of excess risk is observed for each type of AF. Our study indicates that detection of AF, even paroxysmal, should trigger prompt consideration for surgery
    corecore